通常SAN Switch连接设计为:- FT Media Server启用Target 模式的端口连接到SAN Switch(假设1口)

  • Client端口连接到SAN Switch(假设2口)
  • 1口和2口创建一个Zone。

在配置完成后,在JavaConsole中看不到设备,FT Media Server日志中可以看到:

0,51216,137,199,32,1448943642598,14971,1090509120,0:,20:parsing = >7.6.1.2
<,23:parsePatchVersionString,1
0,51216,137,199,33,1448943642598,14971,1090509120,0:,12:theRest = ><,23:parsePatchVersionString,1 \
0,51216,199,199,33,1448943643588,14971,1125271872,0:,16:targets 2 luns 2,35:FTServerMgr_i::listAllPseudoDevices,1
0,51216,199,199,34,1448944596103,14971,1110579520,0:,212:A LOGO or link down was observed on PN=1 for 15 
minutes. Please check the port-switch connectivity. Setting the port speed on the switch to Fixed instead of Auto-negotiate 
has been known to fix some login issues.,23:PerformDeadPortWatchDog,1

Client日志里可看到如下信息:

vxlogview -o 200 -d all

04/12/16 15:06:53.337 [Debug] NB 51216 nbftclnt 200 PID:48890074 TID:1 File ID:200 [No context] 1 /
[FTClientMgr_i::scanDevices] Rescan of FT Devices not supported on this OS in this version

在交换机查看端口状态:

sr-m-san-nbu02:FID128:admin> portstatsshow 8
er_enc_in               26412           Encoding errors inside of frames
er_crc                  2341           Frames with CRC errors

明显可以看到有错误的生成。默认情况下SAN Switch端口速率为N8(自适应),解决办法是将更改连接**FT Media Server Target**的端口为指定速率,4gb是一个推荐值。

sr-m-san-nbu02:FID128:admin> portcfgspeed 
Error in input options
 Usage: portCfgSpeed PortNumber Speed_Level

 OR
        portcfgspeed -i  [-f] Speed_Level

 OR
        portcfgspeed <-slot | -s >  Speed_Level

        -i:            Confirms port swap has been disabled and to give port index as operand
        -x:            Confirms port swap has been disabled and to give port index in HEX format as operand
        -f:            ignores non-existing indexes

        portindex_range: Specifies the range of port index  (example: 12-14)
        Speed_Level:     0  - Auto Negotiate (Hardware)
                         1  - 1Gbps
                         2  - 2Gbps
                         4  - 4Gbps
                         8  - 8Gbps
                        10  - 10Gbps
                        16  - 16Gbps
                        ax  - Auto Negotiate (Hardware) + retries
                        s   - Auto Negotiate (Software)
sr-m-san-nbu02:FID128:admin> portcfgspeed -i 8-16 -f 4

更改后查看端口状态不再有错误增长即为正常,如果Client和FT Media Server连接到了不同的SAN Switch,SAN Switch之间的级连端口也要固定速率。

更改完成后可通过portcfgshow查看配置:

sr-m-san-nbu02:FID128:admin> portcfgshow 8
Area Number:              8
Octet Speed Combo:        1(16G|8G|4G|2G)
Speed Level:              4G
AL_PA Offset 13:          OFF
Trunk Port                ON
Long Distance             OFF
VC Link Init              OFF
Locked L_Port             OFF
Locked G_Port             OFF
Disabled E_Port           OFF
Locked E_Port             OFF
ISL R_RDY Mode            OFF
RSCN Suppressed           OFF
Persistent Disable        OFF
LOS TOV enable            OFF
NPIV capability           ON
QOS Port                  AE
Port Auto Disable:        OFF
Rate Limit                OFF
EX Port                   OFF
Mirror Port               OFF
SIM Port                  OFF
Credit Recovery           ON
F_Port Buffers            OFF
E_Port Credits            OFF
Fault Delay:              0(R_A_TOV)
NPIV PP Limit:            126
CSCTL mode:               OFF
D-Port mode:              OFF
D-Port over DWDM:         OFF
Compression:              OFF
Encryption:               OFF
FEC:                      ON

SAN Switch端口默认启用Trunk,在没有License的情况下并不生效,所以可以忽略,Client连接到SAN Switch的端口启用了NPIV可能会对配置造成影响,这里不做讨论。

如果更改速率后错误仍旧产生,可通过portdisable和portenable禁用启用下端口。