通常SAN Switch连接设计为:- FT Media Server启用Target 模式的端口连接到SAN Switch(假设1口)
- Client端口连接到SAN Switch(假设2口)
- 1口和2口创建一个Zone。
在配置完成后,在JavaConsole中看不到设备,FT Media Server日志中可以看到:
0,51216,137,199,32,1448943642598,14971,1090509120,0:,20:parsing = >7.6.1.2
<,23:parsePatchVersionString,1
0,51216,137,199,33,1448943642598,14971,1090509120,0:,12:theRest = ><,23:parsePatchVersionString,1 \
0,51216,199,199,33,1448943643588,14971,1125271872,0:,16:targets 2 luns 2,35:FTServerMgr_i::listAllPseudoDevices,1
0,51216,199,199,34,1448944596103,14971,1110579520,0:,212:A LOGO or link down was observed on PN=1 for 15
minutes. Please check the port-switch connectivity. Setting the port speed on the switch to Fixed instead of Auto-negotiate
has been known to fix some login issues.,23:PerformDeadPortWatchDog,1
Client日志里可看到如下信息:
vxlogview -o 200 -d all
04/12/16 15:06:53.337 [Debug] NB 51216 nbftclnt 200 PID:48890074 TID:1 File ID:200 [No context] 1 /
[FTClientMgr_i::scanDevices] Rescan of FT Devices not supported on this OS in this version
在交换机查看端口状态:
sr-m-san-nbu02:FID128:admin> portstatsshow 8
er_enc_in 26412 Encoding errors inside of frames
er_crc 2341 Frames with CRC errors
明显可以看到有错误的生成。默认情况下SAN Switch端口速率为N8(自适应),解决办法是将更改连接**FT Media Server Target**的端口为指定速率,4gb是一个推荐值。
sr-m-san-nbu02:FID128:admin> portcfgspeed
Error in input options
Usage: portCfgSpeed PortNumber Speed_Level
OR
portcfgspeed -i [-f] Speed_Level
OR
portcfgspeed <-slot | -s > Speed_Level
-i: Confirms port swap has been disabled and to give port index as operand
-x: Confirms port swap has been disabled and to give port index in HEX format as operand
-f: ignores non-existing indexes
portindex_range: Specifies the range of port index (example: 12-14)
Speed_Level: 0 - Auto Negotiate (Hardware)
1 - 1Gbps
2 - 2Gbps
4 - 4Gbps
8 - 8Gbps
10 - 10Gbps
16 - 16Gbps
ax - Auto Negotiate (Hardware) + retries
s - Auto Negotiate (Software)
sr-m-san-nbu02:FID128:admin> portcfgspeed -i 8-16 -f 4
更改后查看端口状态不再有错误增长即为正常,如果Client和FT Media Server连接到了不同的SAN Switch,SAN Switch之间的级连端口也要固定速率。
更改完成后可通过portcfgshow查看配置:
sr-m-san-nbu02:FID128:admin> portcfgshow 8
Area Number: 8
Octet Speed Combo: 1(16G|8G|4G|2G)
Speed Level: 4G
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
Locked E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
QOS Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port OFF
Mirror Port OFF
SIM Port OFF
Credit Recovery ON
F_Port Buffers OFF
E_Port Credits OFF
Fault Delay: 0(R_A_TOV)
NPIV PP Limit: 126
CSCTL mode: OFF
D-Port mode: OFF
D-Port over DWDM: OFF
Compression: OFF
Encryption: OFF
FEC: ON
SAN Switch端口默认启用Trunk,在没有License的情况下并不生效,所以可以忽略,Client连接到SAN Switch的端口启用了NPIV可能会对配置造成影响,这里不做讨论。
如果更改速率后错误仍旧产生,可通过portdisable和portenable禁用启用下端口。