NetBackup SAN Client光纤连接

通常SAN Switch连接设计为:

  • FT Media Server启用Target 模式的端口连接到SAN Switch(假设1口)
  • Client端口连接到SAN Switch(假设2口)
  • 1口和2口创建一个Zone。
  • 在配置完成后,在JavaConsole中看不到设备,FT Media Server日志中可以看到:

    0,51216,137,199,32,1448943642598,14971,1090509120,0:,20:parsing = >7.6.1.2
    < ,23:parsePatchVersionString,1
    0,51216,137,199,33,1448943642598,14971,1090509120,0:,12:theRest = >< ,23:parsePatchVersionString,1 \
    0,51216,199,199,33,1448943643588,14971,1125271872,0:,16:targets 2 luns 2,35:FTServerMgr_i::listAllPseudoDevices,1
    0,51216,199,199,34,1448944596103,14971,1110579520,0:,212:A LOGO or link down was observed on PN=1 for 15 
    minutes. Please check the port-switch connectivity. Setting the port speed on the switch to Fixed instead of Auto-negotiate 
    has been known to fix some login issues.,23:PerformDeadPortWatchDog,1